counter
Beranda » Alat Ukur » Harga Jual Yokogawa MY10 Insulation Tester

Harga Jual Yokogawa MY10 Insulation Tester

STOK HABIS
Kode : MY10
Berat : 500 gram
Stok : Habis
Kondisi : Baru
Kategori : Alat Ukur
Dilihat : 2.456 kali
Review : Belum ada review
Harga Jual Yokogawa MY10 Insulation Tester

*Pemesanan dapat langsung menghubungi kontak di bawah ini:

Review Spesifikasi dan Harga Jual Yokogawa MY10 Insulation Tester original termurah dan bergaransi resmi *Harga Hubungi CS
Habis / MY10
Maaf, stock habis!
Produk ini tidak tersedia lagi (tidak dapat diorder).

Bagikan informasi tentang Harga Jual Yokogawa MY10 Insulation Tester kepada teman atau kerabat Anda.

Deskripsi Harga Jual Yokogawa MY10 Insulation Tester

ANALOG TESTERS MY10 SERIES

  • Analog models with single rating
    MY10-01:125V/20MΩ
    MY10-02:250V/50MΩ
    MY10-03:500V/100MΩ
    MY10-04:500V/1000MΩ
    MY10-05:1000V/2000MΩ
  • AC voltage measurement
  • Automatic discharge
  • A wide choice of accessories-Designed for shared use with the MY40

Specifications – Model MY10-01

Rating 125V/20MΩ
Effective Measuring Range 0.01-20MΩ
Central Scale Value 0.5MΩ
AC Voltage Measurement 0 to 250 V
Lower Limit 0.125MΩ
Rated Current 1-1.2 mA
Approx. Overall Scale Length 107 mm
Battery Life Approx. 10 hours when continuously operated on manganese – oxide batteries with the pointer pointing to the central scale value.
Batteries Four AA (R6P) batteries
Approx. Width 125 mm
Approx. Height 103 mm
Approx. Depth 53 mm
Approx. Weight 500 g
Compliance EN61010-1:1993; EN61010-2-31:1995 (Overvoltage Category III, Pollution Degree 2 installations for indoor use)
Standard Accessories Batteries (Qty – 4)
Earth Probe (98002) (Qty – 1)
Line Probe (98001) (Qty – 1)
Protection Cover (93013) (Qty – 1)
Shoulder Strap (99005) (Qty – 1)
User’s Manual (Qty – 1)

Standard Test Conditions – Model MY10-01

Ambient Temperature/Humidity Ranges 23 ±5 /45-75% RH
Position of Use Horizontal (5° max. of angle of inclination)
Battery Voltage Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
Tolerance Mentioned Conditions Resistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading
Infinite and zero scale values: 0.7% max. of scale length
AC voltage: ±10% of maximum scale value
No-load voltage: 130% max. of rated voltage
Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
Short-circuit current: 12 mA max.

Additional Functions – Model MY10-01

  • Automatic discharge function
    • If the object under test remains electrified after the MEAS switch is turned off, the tester lets you know by turning on the LED lamp. If you leave the tester connected to the electrified object, the tester automatically begins to discharge electricity and then finishes discharging-the LED lamp comes on and then goes out.
    • When the object under test is capacitive and electrified, the tester lets you know by turning on the LED lamp. When left connected to the object, the tester automatically discharges electricity, thus preventing possible electric shock or spike noise at power-on.
  • Battery check (BAT mark on the scale plate)

 

Specifications – Model MY10-02

Rating 250V/50MΩ
Effective Measuring Range 0.01-50MΩ
Central Scale Value 1MΩ
AC Voltage Measurement 0 to 300 V
Lower Limit 0.25MΩ
Rated Current 1-1.2 mA
Approx. Overall Scale Length 107 mm
Battery Life Approx. 10 hours when continuously operated on manganese – oxide batteries with the pointer pointing to the central scale value.
Batteries Four AA (R6P) batteries
Approx. Width 125 mm
Approx. Height 103 mm
Approx. Depth 53 mm
Approx. Weight 500 g
Compliance EN61010-1:1993; EN61010-2-31:1995 (Overvoltage Category III, Pollution Degree 2 installations for indoor use)
Standard Accessories Batteries (Qty – 4)
Earth Probe (98002) (Qty – 1)
Line Probe (98001) (Qty – 1)
Protection Cover (93013) (Qty – 1)
Shoulder Strap (99005) (Qty – 1)
User’s Manual (Qty – 1)

Standard Test Conditions – Model MY10-02

Ambient Temperature/Humidity Ranges 23 ±5 /45-75% RH
Position of Use Horizontal (5° max. of angle of inclination)
Battery Voltage Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
Tolerance Mentioned Conditions Resistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading
Infinite and zero scale values: 0.7% max. of scale length
AC voltage: ±10% of maximum scale value
No-load voltage: 130% max. of rated voltage
Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
Short-circuit current: 12 mA max.

Additional Functions – Model MY10-02

  • Automatic discharge function
    • If the object under test remains electrified after the MEAS switch is turned off, the tester lets you know by turning on the LED lamp. If you leave the tester connected to the electrified object, the tester automatically begins to discharge electricity and then finishes discharging-the LED lamp comes on and then goes out.
    • When the object under test is capacitive and electrified, the tester lets you know by turning on the LED lamp. When left connected to the object, the tester automatically discharges electricity, thus preventing possible electric shock or spike noise at power-on.
  • Battery check (BAT mark on the scale plate)

 

Specifications – Model MY10-03

Rating 500V/100MΩ
Effective Measuring Range 0.05-100MΩ
Central Scale Value 2MΩ
AC Voltage Measurement 0 to 500 V
Lower Limit 0.5MΩ
Rated Current 1-1.2 mA
Approx. Overall Scale Length 107 mm
Battery Life Approx. 10 hours when continuously operated on manganese – oxide batteries with the pointer pointing to the central scale value.
Batteries Four AA (R6P) batteries
Approx. Width 125 mm
Approx. Height 103 mm
Approx. Depth 53 mm
Approx. Weight 500 g
Compliance EN61010-1:1993; EN61010-2-31:1995 (Overvoltage Category III, Pollution Degree 2 installations for indoor use)
Standard Accessories Batteries (Qty – 4)
Earth Probe (98002) (Qty – 1)
Line Probe (98001) (Qty – 1)
Protection Cover (93013) (Qty – 1)
Shoulder Strap (99005) (Qty – 1)
User’s Manual (Qty – 1)

Standard Test Conditions – Model MY10-03

Ambient Temperature/Humidity Ranges 23 ±5 /45-75% RH
Position of Use Horizontal (5° max. of angle of inclination)
Battery Voltage Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
Tolerance Mentioned Conditions Resistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading
Infinite and zero scale values: 0.7% max. of scale length
AC voltage: ±10% of maximum scale value
No-load voltage: 130% max. of rated voltage
Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
Short-circuit current: 12 mA max.

Additional Functions – Model MY10-03

  • Automatic discharge function
    • If the object under test remains electrified after the MEAS switch is turned off, the tester lets you know by turning on the LED lamp. If you leave the tester connected to the electrified object, the tester automatically begins to discharge electricity and then finishes discharging-the LED lamp comes on and then goes out.
    • When the object under test is capacitive and electrified, the tester lets you know by turning on the LED lamp. When left connected to the object, the tester automatically discharges electricity, thus preventing possible electric shock or spike noise at power-on.
  • Battery check (BAT mark on the scale plate)

 

Specifications – Model MY10-04

Rating 500V/1000MΩ
Effective Measuring Range 0.5-1000MΩ
Central Scale Value 20MΩ
AC Voltage Measurement 0 to 500 V
Lower Limit 1MΩ
Rated Current 0.5-0.6 mA
Approx. Overall Scale Length 107 mm
Battery Life Approx. 10 hours when continuously operated on manganese – oxide batteries with the pointer pointing to the central scale value.
Batteries Four AA (R6P) batteries
Approx. Width 125 mm
Approx. Height 103 mm
Approx. Depth 53 mm
Approx. Weight 500 g
Compliance EN61010-1:1993; EN61010-2-31:1995 (Overvoltage Category III, Pollution Degree 2 installations for indoor use)
Standard Accessories Batteries (Qty – 4)
Earth Probe (98002) (Qty – 1)
Line Probe (98001) (Qty – 1)
Protection Cover (93013) (Qty – 1)
Shoulder Strap (99005) (Qty – 1)
User’s Manual (Qty – 1)

Standard Test Conditions – Model MY10-04

Ambient Temperature/Humidity Ranges 23 ±5 /45-75% RH
Position of Use Horizontal (5° max. of angle of inclination)
Battery Voltage Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
Tolerance Mentioned Conditions Resistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading
Infinite and zero scale values: 0.7% max. of scale length
AC voltage: ±10% of maximum scale value
No-load voltage: 130% max. of rated voltage
Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
Short-circuit current: 12 mA max.

Additional Functions – Model MY10-04

  • Automatic discharge function
    • If the object under test remains electrified after the MEAS switch is turned off, the tester lets you know by turning on the LED lamp. If you leave the tester connected to the electrified object, the tester automatically begins to discharge electricity and then finishes discharging-the LED lamp comes on and then goes out.
    • When the object under test is capacitive and electrified, the tester lets you know by turning on the LED lamp. When left connected to the object, the tester automatically discharges electricity, thus preventing possible electric shock or spike noise at power-on.
  • Battery check (BAT mark on the scale plate)

 

Specifications – Model MY10-05

Rating 1000V/2000MΩ
Effective Measuring Range 1-2000MΩ
Central Scale Value 50MΩ
AC Voltage Measurement 0 to 500 V
Lower Limit 2MΩ
Rated Current 0.5-0.6 mA
Approx. Overall Scale Length 107 mm
Battery Life Approx. 10 hours when continuously operated on manganese – oxide batteries with the pointer pointing to the central scale value.
Batteries Four AA (R6P) batteries
Approx. Width 125 mm
Approx. Height 103 mm
Approx. Depth 53 mm
Approx. Weight 500 g
Compliance EN61010-1:1993; EN61010-2-31:1995 (Overvoltage Category III, Pollution Degree 2 installations for indoor use)
Standard Accessories Batteries (Qty – 4)
Earth Probe (98002) (Qty – 1)
Line Probe (98001) (Qty – 1)
Protection Cover (93013) (Qty – 1)
Shoulder Strap (99005) (Qty – 1)
User’s Manual (Qty – 1)

Standard Test Conditions – Model MY10-05

Ambient Temperature/Humidity Ranges 23 ±5 /45-75% RH
Position of Use Horizontal (5° max. of angle of inclination)
Battery Voltage Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
Tolerance Mentioned Conditions Resistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading
Infinite and zero scale values: 0.7% max. of scale length
AC voltage: ±10% of maximum scale value
No-load voltage: 130% max. of rated voltage
Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
Short-circuit current: 12 mA max.

Additional Functions – Model MY10-05

  • Automatic discharge function
    • If the object under test remains electrified after the MEAS switch is turned off, the tester lets you know by turning on the LED lamp. If you leave the tester connected to the electrified object, the tester automatically begins to discharge electricity and then finishes discharging-the LED lamp comes on and then goes out.
    • When the object under test is capacitive and electrified, the tester lets you know by turning on the LED lamp. When left connected to the object, the tester automatically discharges electricity, thus preventing possible electric shock or spike noise at power-on.
  • Battery check (BAT mark on the scale plate)

 

 

yokogawa MY10 Insulation Tester

Belum ada ulasan untuk produk Harga Jual Yokogawa MY10 Insulation Tester

Silahkan tulis ulasan Anda

Your email address will not be published.

*







Produk Terkait Harga Jual Yokogawa MY10 Insulation Tester

QUICK ORDER
Harga Jual Hanna Instruments HI-711 Pocket Checker for Total Chlorine Testing

*Pemesanan dapat langsung menghubungi kontak di bawah ini:

Review Spesifikasi dan Harga Jual Hanna Instruments HI-711 Pocket Checker for Total Chlorine Testing original termurah dan bergaransi resmi *Harga Hubungi CS
Ready Stock / HI-711
QUICK ORDER
Harga Jual Cable Tester Low Voltage

*Pemesanan dapat langsung menghubungi kontak di bawah ini:

Review Spesifikasi dan Harga Jual Cable Tester Low Voltage original termurah dan bergaransi resmi Rp 6.858.100
Ready Stock / BBM3
Rp 6.858.100
Ready Stock / BBM3
STOK HABIS
Harga Jual Testo 511 Absolute Pressure Meter

*Pemesanan dapat langsung menghubungi kontak di bawah ini:

Review Spesifikasi dan Harga Jual Testo 511 Absolute Pressure Meter original termurah dan bergaransi resmi *Harga Hubungi CS
Habis / T511
*Harga Hubungi CS
Habis / T511

Mungkin Anda tertarik dengan produk terbaru kami

STOK HABIS
Harga Jual Topcon ES-102

*Pemesanan dapat langsung menghubungi kontak di bawah ini:

Review Spesifikasi dan Harga Jual Topcon ES-102 original termurah dan bergaransi resmi *Harga Hubungi CS
Habis
*Harga Hubungi CS
Habis
QUICK ORDER
Harga Teleskop Bintang Celestron Powerseeker 70AZ

*Pemesanan dapat langsung menghubungi kontak di bawah ini:

Rp 2.386.000
Ready Stock / 21036
STOK HABIS
AF4915ZT Dinolite Edge

*Pemesanan dapat langsung menghubungi kontak di bawah ini:

Rp 16.533.000
Habis
Rp 16.533.000
Habis
SIDEBAR